|  | Motor Connecting Cables |  | |
|  | |||
| 2YSLCY-JB/2YSLCYK-JB |  |  | 9YSLCY-JB |  | PENDANT CABLE |  | 
 Mineral insulated cables
Mineral insulated cables
      Fluoropolymer-insulated Heating Cable up to 260 °C with Protective Braid Cu/Ni
Application
Vessels, piping, valves
Small components
Industrial areas
Rotor blades
Marble plates
Standard
DIN VDE 0253
Voltage Rating
750V
CABLE CONSTRUCTION

Heating conductor.
Insulation: Fluoropolymer.
Protective: Nickel-plated copper braid.
Mechanical and Thermal Properties
Maximum operating temperature: 260℃
Minimum installation temperature: -60℃
Minimum bending radius: 2.5xOD
Maximum output: 30 W/m
Nominal resistance of heating conductor: 8000 Ω/km
Cable Parameter
| Nominal resistance | APPROX. | 7APPROX. | Temperature coefficient | 
|---|---|---|---|
| 1.95 (Cu 10mm²) | 7.11 | 157.0 | 4.3 | 
| 2.90 (Cu 6mm²) | 5.99 | 104.9 | 4.3 | 
| 4.40 (Cu 4mm²) | 4.73 | 69.8 | 4.3 | 
| 7.20 (Cu 2.5mm²) | 3.89 | 48.3 | 4.3 | 
| 10.0 | 3.62 | 40.6 | 4.3 | 
| 11.7 (Cu 1.5mm²) | 3.53 | 37.6 | 4.3 | 
| 15.0 | 3.20 | 33.6 | 4.3 | 
| 25.0 | 3.15 | 31.1 | 3.0 | 
| 31.5 | 3.55 | 39.6 | 1.6 | 
| 50.0 | 3.15 | 31.3 | 1.6 | 
| 65.0 | 3.04 | 28.6 | 1.6 | 
| 80.0 | 3.32 | 34.5 | 0.9 | 
| 100.0 | 3.11 | 31.0 | 0.9 | 
| 157.0 | 3.10 | 31.2 | 0.45 | 
| 180.0 | 2.84 | 25.8 | 0.45 | 
| 200.0 | 2.98 | 28.2 | 0.45 | 
| 260.0 | 2.87 | 26.3 | 0.45 | 
| 280.0 | 2.76 | 24.3 | 0.38 | 
| 328.0 | 3.13 | 30.6 | 0.18 | 
| 360.0 | 2.71 | 23.7 | 0.45 | 
| 430.0 | 2.96 | 27.6 | 0.18 | 
| 480.0 | 2.94 | 26.8 | 0.18 | 
| 600.0 | 2.80 | 24.9 | 0.18 | 
| 800.0 | 2.69 | 23.2 | 0.18 | 
| 1000.0 | 2.81 | 24.9 | 0.04 | 
| 1470.0 | 2.64 | 22.6 | 0.04 | 
| 1750.0 | 2.66 | 22.3 | 0.04 | 
| 1900.0 | 2.84 | 25.6 | 0.40 | 
| 2900.0 | 2.68 | 23.1 | 0.40 | 
| 4000.0 | 2.61 | 21.9 | 0.40 | 
| 4700.0 | 2.55 | 21.6 | 0.15 | 
| 6000.0 | 2.49 | 20.6 | 0.20 | 
| 7000.0 | 2.43 | 19.9 | 0.15 | 
| 8000.0 | 2.41 | 19.7 | 0.15 | 